Images are representations only.

710FMO Solenoid Valve (FKM), Flanged, Manual Override

Brand: Morrison Bros. Co.
Normally closed solenoid valves are used to help prevent the accidental siphoning of a product from a tank in the event of a leak downstream below the liquid level.

They are generally installed on the dispensing side of a fuel system pipeline.

The valve opens upon the receipt of an electronic signal such as when a dispenser or pump is switched to the ‘on’ position.
Features
  • Normally closed, hung piston design
  • Install in a horizontal pipeline in the upright vertical position
  • Minimum operating temperature is -40° F
  • Zero pressure differential
  • Integral thermal relief allows the valve to relieve expansion pressure in the opposite direction of flow
  • Continuous duty Class H standard coil operates at 120 volts
  • Enclosure is watertight and rated for hazardous locations - NEMA 3, 4X, 7 and 9; groups C and D
  • Several optional coil voltages available
  • 710MO has manual override feature. Available in sizes ranging from 3/4″ to 2″ for operation during a power outage
  • Recommended for use with liquids having a maximum viscosity of 60 centistokes
  • A strainer with a 100 mesh screen is recommended at the valve inlet
show more
Normally closed solenoid valves are used to help prevent the accidental siphoning of a product from a tank in the event of a leak downstream below the liquid level.

They are generally installed on the dispensing side of a fuel system pipeline.

The valve opens upon the receipt of an electronic signal such as when a dispenser or pump is switched to the ‘on’ position.
Features
  • Normally closed, hung piston design
  • Install in a horizontal pipeline in the upright vertical position
  • Minimum operating temperature is -40° F
  • Zero pressure differential
  • Integral thermal relief allows the valve to relieve expansion pressure in the opposite direction of flow
  • Continuous duty Class H standard coil operates at 120 volts
  • Enclosure is watertight and rated for hazardous locations - NEMA 3, 4X, 7 and 9; groups C and D
  • Several optional coil voltages available
  • 710MO has manual override feature. Available in sizes ranging from 3/4″ to 2″ for operation during a power outage
  • Recommended for use with liquids having a maximum viscosity of 60 centistokes
  • A strainer with a 100 mesh screen is recommended at the valve inlet

Specifications

Certifications & Approvals

  • CSA
  • cULus

Body Material

  • Cast bronze

Material of Construction

  • Seal: FKM

Environmental Protection

  • NEMA 3, 4X, 7 and 9

Voltage

  • 120 Vac (24, 208, 220, 240, & 480 Vac, and 12, 24, and 48 Vdc available)

Operating Temperature

  • Minimum -40° F

Size

  • 2"

Applications

  • Storage Tank