Description
- High accuracy, better than 0.1% of span
 - Slimline housing of 6 mm
 - Excellent EMC performance and 50/60 Hz noise suppression
 - Selectable < 30 ms / 300 ms response time
 - Pre-calibrated temperature ranges are selectable via DIP-switches
 
- Flexibly powered by 24 VDC (±30%) via connectors.
 - < 30 ms fast response time with simultaneous sensor error detection when selected.
 - Selectable 300 ms response time when signal dampening is needed.
 - High conversion accuracy in all available ranges, better than 0.1% of span.
 - Meeting the NAMUR NE21 recommendations, the 3102 provides top measurement performance in harsh EMC environments.
 - The device meets the NAMUR NE43 standard defining out of range and sensor error output values.
 - A visible green LED indicates operational status of the unit and the input sensor.
 - All terminals are protected against overvoltage and polarity error.
 - Excellent signal/noise ratio of > 60 dB.
 
Specifications
Specifications
Brand
Accuracy
- ± 0.1 %
 
Approvals & Certifications
- ATEX 2014/34/EU KEMA 10-ATEX-0147 X, II 3 G Ex NA IIC T4 Gc
 - DNV Marine Standard F. Certificate No. 2.4
 - EAC TR CU 020/2011
 - EMC 2014/30/EU
 - FM 3041043-C
 - GL V1-7-2
 - IECEx KEM 10.0068X
 - LVD 2014/35/EU
 - RoHS 2011/65/EU
 - UL 61010-1
 
Calibration
- 20° to 28° C (68° to 82° F)
 
Environmental Protection
- IP20
 
Humidity
- < 95 % RH, Non-Condensing
 
Load
- ≥ 10 kΩ
 
Output
- 0-10 V / 2 to 10 V Programmable Signal Ranges
 - 0-23 mA Signal Range
 - 0-5 V / 1-5 V Programable Signal Ranges
 - 4-20 mA Programmable Signal Ranges
 
Response Time
- < 30 ms / 300 ms (Selectable)
 
RTD Type
- Pt100 Temperature Range -200° to 850° C (-328° to 1562° F)
 
Storage Temperature
- -40° to 85° C (-40° to 185° F)
 
Supply Voltage
- 16.8-31.2 Vdc
 
Temperature Range
- -25° to 70° C (-13° to 160° F)
 
Vibration
- ± 1.6 mm
 - ± 4 G
 
Applications
Applications
- The 3102 temperature converter measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and provides an analog voltage or current output.
 - The 3102 can be mounted in the safe area or in Zone 2 / Division 2 areas.
 - Approved for marine applications.