Images are representations only.

ST-15-WX Overfill Prevention and Liquid Detection Monitor

Brand: Scully Signal Company
The Scully ST-15-WX series multiple point liquid level detection control units are available in two through twelve channel models. The ST-15-WX is commonly used to provide overfill protection, high level warning, low level warning and/or pump and valve control functions. 

They are well suited for multiple fixed storage tank and transport tank applications where individual display and/or output control is required. The output control function may be reversed to alarm for a dry sensor condition rather than a wet sensor condition for low level warning. 

The ST-15-WX enclosure includes individual red indicator lamps that light when a sensor is wetted, a power indicator lamp, an alarm acknowledge push button and alarm test push button. Once a sensor alarm is acknowledged the alarm output circuit is reset, however, the indicator lamp remains lit until the sensor is dry again.
Features
  • Incorporates Dynamic Self-Checking™ circuitry which monitors the controller, wiring, connections and sensors for faults thirty times per second
  • Signals an audible alarm and/or controls pumps and valves for automatic shutdown
  • Monitors from 2 –12 total sensing points depending on model 
  • Provides liquid level detection for a wide variety of petroleum and chemical products
  • Uses output sensors approved as intrinsically safe for use in Class 1, Division 1, Group D hazardous environments 
  •  NEMA 4 style watertight housings
  • Works in conjunction with either Scully field-proven thermistor or Instant-On optic sensors
The Scully ST-15-WX series multiple point liquid level detection control units are available in two through twelve channel models. The ST-15-WX is commonly used to provide overfill protection, high level warning, low level warning and/or pump and valve control functions. 

They are well suited for multiple fixed storage tank and transport tank applications where individual display and/or output control is required. The output control function may be reversed to alarm for a dry sensor condition rather than a wet sensor condition for low level warning. 

The ST-15-WX enclosure includes individual red indicator lamps that light when a sensor is wetted, a power indicator lamp, an alarm acknowledge push button and alarm test push button. Once a sensor alarm is acknowledged the alarm output circuit is reset, however, the indicator lamp remains lit until the sensor is dry again.
Features
  • Incorporates Dynamic Self-Checking™ circuitry which monitors the controller, wiring, connections and sensors for faults thirty times per second
  • Signals an audible alarm and/or controls pumps and valves for automatic shutdown
  • Monitors from 2 –12 total sensing points depending on model 
  • Provides liquid level detection for a wide variety of petroleum and chemical products
  • Uses output sensors approved as intrinsically safe for use in Class 1, Division 1, Group D hazardous environments 
  •  NEMA 4 style watertight housings
  • Works in conjunction with either Scully field-proven thermistor or Instant-On optic sensors
Models matching criteria: 11
ST-15-WX2 Two Channel/Sensing Point Control Unit
ST-15-WX3, Three Channel/Sensing Point Control Unit
ST-15-WX4, Four Channel/Sensing Point Control Unit
ST-15-WX5, Five Channel/Sensing Point Control Unit
ST-15-WX6, Six Channel/Sensing Point Control Unit
ST-15-WX7, Seven Channel/Sensing Point Control Unit
ST-15-WX8, Eight Channel/Sensing Point Control Unit
ST-15-WX9, Nine Channel/Sensing Point Control Unit
ST-15-WX10, Ten Channel/Sensing Point Control Unit
ST-15-WX11, Eleven Channel/Sensing Point Control Unit
ST-15-WX12, Twelve Channel/Sensing Point Control Unit

Specifications

Certifications & Approvals

  • SIL

Product Range

  • Gasoline Through #6 Oil, Waste Oil, Chemicals, Water, etc.

Indicator Light

  • Green = Power On
  • Red = Alarm Condition

Response Time

  • High-level: 0.05 seconds maximum
  • Low-level: 3-7 seconds

Environmental Protection

  • NEMA 4

Power Requirement

  • 115 Vac, ± 15 %, 50-60 Hz, 20 W Max.
  • 240 Vac

Electrical Connection

  • Internal Terminal Strips

Output Provision

  • External Alarm, 115 Vac, 3 A Max.
  • Individual Channel SPDT Contacts, Rated 5 to 250 Vac

Applications

  • Chemical Applications