Description
- Potentiometer or Ohmic input
- Programmable sensor error value
- High measurement accuracy
- Unique process calibration function
- Programmable via standard PC
- Within a few seconds the user can program PR5343A to measure within the defined Ohmic values.
- Continuous check of vital stored data for safety reasons.
- The transmitter is protected against polarity reversal.
- PR5343A is configured to the current task by way of a PC, the PReset software and the communications interface Loop Link.
- The PRelevel configuration tool included in the PReset software has been developed specifically for the configuration of level applications. Among other things, it contains a function for ”on line” measurement of input span as well as a linearization function for volume linear output from horizontal cylindrical tanks.
Specifications
Specifications
Brand
Accuracy
- Better than 0.1 % of Selected Range
Approvals & Certifications
- ATEX 2014/34/EU KEMA 10-ATEX-0004 X
- CE
- DNV Marine Standard F. Certificate No. 2.4
- EAC TR CU 020/2011
- EMC 2014/30/EU
- Ex
- GL V1-7-2
- IECEx dEK 13.0036X
- INMETRO DEKRA 13.0002 X
Connection Style
- Screw Terminals
Consumption
- 25 mW to 0.8 W
Dimensions
- 1.73” (Diameter) x 0.80” (44 x 20.2 mm)
Environmental Protection
- IP00
- IP68
Humidity
- < 95 % Relative Humidity, Non-Condensing
Input
- 25 µA - Sensor Current
Output
- 16 mA - Min. Output Signal Range
- 23 mA - Upscale
- 3.5 mA - Downscale
- 4-20 mA
Output Function
- NAMUR NE 43
Output Noise
- Minimum 60 dB - Signal to Noise Ratio
Power Supply Effect
- ± 0.005 % of Span Per Volt
Resistance
- 0 to 100 kiloohms / 1 kiloohms - Linear Resistance Input
- 100 ohms - Max.
Resolution
- 16-bit - Signal Dynamics, Output
- 19-bit - Signal Dynamics, Input
Response Time
- 0.33 to 60 seconds
Sensor, Probe Connection
- 3-Wire
Stability
- ≤ 0.01 % of Span at 100 ohms - Load
Supply Voltage
- 8-35 Vdc
Temperature Range
- 20° to 28° C (68° to 82.4° F) - Calibration Temperature
- -40° to 85° C (-40° to 185° F)
Torque
- 3.54 In/Lbs (0.4 Nm) - Screw Terminal Torque
Update Time
- 135 milliseconds
- 5 minutes - Warm-Up Time
Vibration
- ± 1.6 mm at 2 to 25 Hz as Per IEC 60068-2-6: 2007
- ± 4 G at 25 to 100 Hz as Per IEC 60068-2-6: 2007
Voltage Drop
- 8 Vdc
Zero Offset
- 50 % of Selected, Max.
Applications
Applications
- Conversion of resistance variation to standard analog current signals, e.g. from Ohmic level sensors or valve positions.
- User-defined linearization function can be activated.