Intellicheck 3 Complete Overfill Prevention & Retained Product Monitoring System
Description
The Scully IntelliCheck®3 Multi-Level is a state-of-the-art, multi-compartment dual overfill monitoring system and newest addition to our family of superior on-board safety monitoring systems.
The IntelliCheck®3 Multi-Level is suitable for use on vehicles with up to five compartments requiring two levels of monitoring. It ensures maximum safety for proper sensor response should a High or High-High level (overfill) condition occur.
IntelliCheck®3 is the safest and most advanced tank trailer overfill prevention and retained product monitoring system.
It saves time and money by reducing down-time and ensuring safe, dependable loading operations.
FeaturesOverfill Prevention
- Advanced, easy-to-understand diagnostics with Bi-color LEDs
- High-level detection in each vehicle compartment, using either Scully 2 Wire or 5 Wire sensors
- Simplified programming
- System shutdown within one-half second of high-level or fault condition detection.
- Individual sensor indicators for static conditions such as “wet” sensor or operational faults
- New 5 Wire Series Wired Sensor compatibility adds diagnostic capability to 5 wire vehicles.
- Detects opens, shorts and helps pinpoint specific sensor to save time in troubleshooting
- Prevents bypassing sensors for maximum safety
- RoHS compliant design to protect the environment
- Corrosion resistant housing
- Impact and UV resistant window for improved performance
- Dual Level model available to detect and control 2 sensors per compartment
Dynacheck® Safety
- Complete automatic and continuous checking of all system components for static operation
- Complete system diagnostics
- Visual indication of Dynacheck® self-checking, sensor status and fault conditions
- Indicator for auxiliary switch operation, such as vapor interlock
- Loading rack connection indicators
Retained Product Monitoring
- Retained product detection using two-wire optic sensors
- Loading “lock-out” feature if vehicle returns with product
- Driver must press retained product acknowledge button for loading to occur
- Helps prevent product mixing
- Warns against overfilling of vehicle compartments
Advanced Optic Sensing
- Scully optic sensors are used as the "eyes" of the Intellicheck®3 to determine loading status
- Each sensor is independently monitored and tested up to 30 times per second
- Withstands extreme road and temperature conditions.
- IntelliCheck® Kits include Scully sensors- the most reliable sensors in the market with nearly double the warranty of any other sensor.
Inventory
Displaying prices & availability for Ohio, United States in CAD. Change location.
Featured
- Featured
- Quantity In Stock
- Price
- SKU / Model Number
Models matching criteria: 21
IntelliCheck®3 Overfill Control Monitor
Intellicheck®3-R Upgrade Kit, Overfill and Retained
IntelliCheck®3 Dual Level Monitor
Intellicheck®3-R Upgrade Kit, Overfill 8 view more
The Scully IntelliCheck®3 Multi-Level is a state-of-the-art, multi-compartment dual overfill monitoring system and newest addition to our family of superior on-board safety monitoring systems.
The IntelliCheck®3 Multi-Level is suitable for use on vehicles with up to five compartments requiring two levels of monitoring. It ensures maximum safety for proper sensor response should a High or High-High level (overfill) condition occur.
IntelliCheck®3 is the safest and most advanced tank trailer overfill prevention and retained product monitoring system.
It saves time and money by reducing down-time and ensuring safe, dependable loading operations.
Intellicheck®3-R Upgrade Kit, Overfill and Retained view more
The Scully IntelliCheck®3 Multi-Level is a state-of-the-art, multi-compartment dual overfill monitoring system and newest addition to our family of superior on-board safety monitoring systems.
The IntelliCheck®3 Multi-Level is suitable for use on vehicles with up to five compartments requiring two levels of monitoring. It ensures maximum safety for proper sensor response should a High or High-High level (overfill) condition occur.
IntelliCheck®3 is the safest and most advanced tank trailer overfill prevention and retained product monitoring system.
It saves time and money by reducing down-time and ensuring safe, dependable loading operations.
Intellicheck®3-R Upgrade Kit, Dual Level
Cover Assembly (Cover, Window, Gasket, Screw, Lockwasher)
Cover
Window
Gasket, Cover
Screw, Hex Head, 10-24 x 3/4", Stainless Steel
Lockwasher, Split, #10, Stainless Stee
Replacement Module, Overfill
Replacement Module, Overfill & Retained
Replacement Module, Dual Level view more
The Scully IntelliCheck®3 Multi-Level is a state-of-the-art, multi-compartment dual overfill monitoring system and newest addition to our family of superior on-board safety monitoring systems.
The IntelliCheck®3 Multi-Level is suitable for use on vehicles with up to five compartments requiring two levels of monitoring. It ensures maximum safety for proper sensor response should a High or High-High level (overfill) condition occur.
IntelliCheck®3 is the safest and most advanced tank trailer overfill prevention and retained product monitoring system.
It saves time and money by reducing down-time and ensuring safe, dependable loading operations.
Base, 1/2” NPT Conduit Entries
Switch Assembly, Reset
Pipe Plug, 1/2" NPT
Standoff, Male-Female, 5/16" Hex, 10-32 x 7/8" Lg., Aluminum
Fuse and Holder, In-Line, 1/2 AMP
Fuse Only
Specifications
Specifications
Temperature Range
- Operating: -40° to +60° C (-40° to +140° F)
- Storage: -45° to +85° C (-50° to +185° F)
Power Requirement
- Consumption: 9.6 Watts Max. at 24 Vdc
- Consumption: 4.8 Watts Max. at 12 Vdc
- Nominal Voltage: 12 to 24 Vdc (-0.5, +8 Vdc)
Outside Dimensions
- 9.26" Wide x 6.81" High x 2.54" Deep
Weight
- 2.7 kg (6.lb)
Interface Inputs:
- TB4 & TB5 Sensor Inputs: EN 13922 Compliant
- TB3 Auxiliary: I.S. Input Switch Closure Less Than 100 ohms
Interface Outputs:
- TB7: 2.0 A at 32 Vdc Max. Non-intrinsically Safe Relay
- TB6 Rack Interface: EN 13922 Compliant I.S. Interface for 2/5- Wire Sensors
- TB6: Intrinsially safe relay output. 200 mA at 32 Vdc Max. or 1.6A at 16 Vdc Max.
APPROVALS
- Canada and the United States: Class I, Div. 2, Group CD, T6, Type 4 or Class I, Zone 2, IIB T6, IP65 With intrinsically Safe Outputs for Class I, Div. 1, Group CD Class 1, Zone 0, IIB Locations