Description
The Intellitrol®2 is intended to serve as a secondary overfill protection system for loading operations. It is intended for use in hazardous locations and is packaged in an explosion-proof (flameproof) enclosure and has both International and US approvals and certifications.
The Intellitrol®2 performs a variety of monitoring functions and provides a number of outputs to control valves, pumps and other systems including Terminal Automation Systems (TAS). It has an integrated display to indicate system and monitoring status, a bypass capability, and communications for integration with TAS and other systems.
The Intellitrol®2 contains a pair of microprocessors, each with its own relay, that monitors critical functions. Only when both processors detect a safe condition will both relays close and make outputs permissive.
The Intellitrol®2 is designed to be Faylsafe® and in the event of a failure (power, sensors, or internal electronics) the unit will enter a non-permissive (safe) state.
This state-of-the-art Dynamic Self-Testing® system controller provides overfill prevention, vehicle ground verification and vehicle identification operating in a single enclosure. The Intellitrol®2 also provides the user with comprehensive diagnostic information, both locally on the exterior of the control unit housing and remotely to the terminal automation system via RS-485 communications.
Features- Overfill prevention, ground verification and vehicle identification in one compact state of the art explosion-proof enclosure
- Scully Dynacheck® automatic and continuous self-checking circuitry
- Automatic detection of two-wire optic/thermistor or five-wire optic vehicle sensors
- Monitoring of up to 8 two-wire or 15 five-wire vehicle sensors
- Complete visual diagnostic display of overfill sensors’ status. Will not permit loading under any fault or wet sensor condition
- When used with Scully Sensors, the Scully Intellitrol®2 Control Unit has been certified as part of a SIL 2 Overfill Prevention System
- Easy connection to vehicles with rugged high impact industry standard plug and cable units
Configure
Specifications
Specifications
Certifications & Approvals
- SIL 2
- CE
- cFMus
- ATEX
- IECEx
- CSA
Communication
- RS-485
- RTU
Response Time
- 450 ms
Operating Temperature
- -40° to +60° C (-40° to +140° F)
Storage Temperature
- -45° to +85° C (-50° to +185° F)
Power Requirement
- 100-130 Vac (120 Vac Setting)
- 200-250 Vac (240 Vac Setting) 50/60 Hz, 30 Watts Max.
Environmental Protection
- Type 4X and IP 65
- NEMA 4X
- IP65
Sensor Input
- Up to 8 Scully Two-wire Optic/Thermistor Sensors (6 or 8 Channels) or 15 Five-wire Optic Sensors (Max.)