Description
- Front-programmable
- mA, V, and Ω programmable input
- Ramp times, jump values, reversal, chopper frequency, and deadband
- 3-digit LED display shows I-valve % value
- 1 or 2 channels
- Multifunction user interface consisting of three pushbuttons and a 3-digit LED display.
- All parameters are protected against unauthorized changes with a password.
- During operation the display shows the present output signal as a % of the I valve.
- Programmable current or voltage input for standard signals acc. to order schedule, joystick / potentiometer or a special non-programmable input.
- Digital inputs for external control functions.
- A pulsating current output prevents the connected valve from sticking.
- Optional programming of the modulation frequency (PWM) between 8 and 400 Hz.
- Multiple adjustable parameters such as output currents, ramp times, jump values, chopper frequency, reversal, deadband, and ON/OFF functions.
- Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.
Configure
Specifications
Specifications
Brand
Accuracy
- Better than 0.2 % of Selected Range
Approvals & Certifications
- CE
- EAC TR CU 020/2011
Consumption
- 1.8 W at 12 V
- 2 W at 24 V
Current
- 7 A - Current Peak
Deadband
- 0 to 99.9 % of Input Span
Dimensions
- 3.17” x 1.40” x 3.33” {80.5 x 35.5 x 84.5 mm (H x W x D)} - D is without Pins
Display
- 3-Digit LED Display
Environmental Protection
- IP50
Frequency
- 8 to 400 Hz in Steps of 1 Hz - PWM Frequency
Humidity
- < 95 % Relative Humidity
Input
- ± 10 V at 10 kiloohms - Potentiometer Input
- 0.2 to 1 V
- 0-1 V
- 0-10 V
- 0-10 V - Potentiometer Input
- 0-20 mA
- 2 to 10 V
- 4-20 mA
Linearization
- 0.2 % - Linearity Error
Mounting
- DIN Rail Mounting
Output
- ± 10 Vdc (A & B Valve) - Reference Voltage
- 10 Vdc (A Valve) - Reference Voltage
- 3,000 mA Mean
Power
- Maximum
Programming
- 3 Push Buttons
Resistance
- 10 megaohms - Voltage Input Resistance
- 50 ohms + PTC (54 ohms) - Current Input Resistance
Span & Zero Effect
- < 2 % of Span - EMC Immunity Influence
Supply Voltage
- 19.2-28.8 Vdc
- 9.6-14.4 Vdc
Temperature Effect
- 0.01 %/°C - Temperature Coefficient
Temperature Range
- -20° to 60° C (-4° to 140° F)
Update Time
- 30 milliseconds
Applications
Applications
- Control and regulation of single- or double-coil hydraulic and pneumatic proportional valves used for accurate oil flow regulation, linear soft acceleration and deceleration, modulated output signal, and programmable deadband.
- Is highly suitable for joystick regulation of A/B movements.
- Where changes to A and B need to be selected directly or according to the value of an input signal.