Maximum Flow Rate
- Continuous Rating with Standard Trim: 1600 USGPM / 2300 BPH / 6075 L/min / 365 m³/h
- Intermittent Rating with Standard Trim: 1750 USGPM / 2500 BPH / 6625 L/min / 400 m³/h
- Continuous Rating with All Iron or LPG Trim: 1200 USGPM / 1725 BPH / 4550 L/min / 275 m³/h
Viscosity
- Standard: 400 mPa.s³ (2,000 SSU) maximum
- Optional: 2 Pa.s (10,000 SSU) maximum - specify "High Viscosity Meter Clearances."
- Over 2 Pa.s: Specify "High Viscosity Meter Clearances" and derate maximum flow rate in direct proportion to viscosity over 2 Pa.s (e.g., at 4 Pa.s, derate maximum flow rate to 50 % of normal continuous rating - 800 USGPM).
Temperature - Standard Meter Clearances with
- Buna-N/PTFE: -20° to 137° F (-29° to 58° C)
- Viton: 10° to 150° F (-12° to 58° C)
Temperature - High Temperature Meter Clearances with
- Buna-N/PTFE: -20° to 200° F (-29° to 93° C)
- Viton: 10° to 200° F (-12° to 93° C)
Temperature - All Iron Trim with
- Buna-N: -20° to 225° F (-29° to 108° C)
- PTFE: -20° to 400° F (-29° to 205° C)
- Viton: 10° to 400° F (-12° to 205° C)