Description
- Measures DC inputs up to ±300 V / ±100 mA with spans as low as 25 mV / 0.5 mA
- Passive/active current output and buffered voltage output
- Fast < 20 ms response time and excellent 0.05% accuracy
- Universally powered by 21.6…253 VAC / 19.2...300 VDC
- The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
- Possibility of output safety readback by selecting S4...20 mA output.
- The current output can drive up to 1000 Ohms, with an adjustable response time of 0.0…60.0 seconds.
- Exceptional mA output load stability of < 0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.
- Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
- Excellent signal to noise ratio of > 60 dB.
Specifications
Specifications
Brand
Approvals & Certifications
- EAC
- SIL
- cULus, UL 508 E248256
- LVD 2014/35/EU
- EMC 2014/30/EU
- RoHS 2011/65/EU
- EAC TR-CU 020/2011
Environmental Protection
- IP20
Humidity
- < 95 % Relative Humidity, Non-Condensing
Operating Temperature
- -20° to 60° C
Storage Temperature
- -20° to 85° C
Calibration Temperature
- 20° to 28° C
Mounting
- DIN Rail EN 607 15/35 mm
Supply Voltage
- 21.6-253 Vac, 50/60 Hz
- 19.2-300 Vdc
Required Power
- ≤ 2.5 W
Response Time
- < 20 milliseconds
Accuracy
- Better than 0.05 % of Selected Range
Input Signal
- ± 100 mA
- ± 300 Vdc
Resistance
- Calibration: 5 k Ω
- Minimum Potentiometer: 200 Ω
Output Signal
- 0 to 23 mA (Unipolar)
- -23 to 23 mA (Bipolar)
- Custom Config. Output Rrange: ± 20 mA
- Minimum Signal Range: 4 mA
Applications
Applications
- Fast < 20 ms response time for measuring signals produced by torque, position, current & acceleration sensors.
- User configurable bipolar or unipolar I/O means the 4184 is suitable for nearly any DC voltage or current conversion.
- Freely programmable between ±300 VDC and ±100 mA.
- The excitation source allows measurement of a 2-wire or 3-wire transmitter, or a potentiometer.
- Converts narrow bipolar inputs to wide bipolar or unipolar outputs, e.g., ±1 volt input = ±10 volt or 4...20 mA output.
- Configurable input limits control the output value for increased safety.
- ±20 VDC buffered voltage output for controlling devices like the PVG 32 valve (6...18 VDC).
- Designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
- Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
Documentation
Documentation
Product Manuals
- 4184 Universal uni-/bipolar signal transmitter Manual in Russian pdf 1.5 MB
- Modbus configuration manual pdf 642 KB
- Product Manual - 4184 Universal uni-/bipolar signal transmitter pdf 1.5 MB
- Product Manual - 4184 Universal uni-/bipolar signal transmitter pdf 1.5 MB
- Product Manual - 4184 Universal uni-/bipolar signal transmitter pdf 1.5 MB