Description
The Messenger W is a basic SCADA monitoring system for small lift or pump stations, flow meters, level devices and power sources. The system monitors fixed assets in the field and transmits the data over a cellular network to RemoteIQ™ for alarm notifications, reports and more.
- Alarm notifications via email, text message or voice calls
- Three digital or pulse inputs capable of monitoring level, pumps, run-times or cycles and computing flow rates
- One analog input for monitoring flow, level, temperature, pH, UV or any other type of current input
- One Form C 12A relay output can be controlled remotely to turn a field device on or off, or used to activate a local audio or visual device such as a horn or light based on a critical event
- LTE cellular modem
- Status LEDs for power, alarms and modem communication
- Terminal blocks for easy wiring
- Achieve optimal equipment performance with RemoteIQ:
- Manage reports, alarm notifications, configuration changes and user login credentials
- Remotely monitor and control pumps, valves and other field devices
- View historical data, current alarms and trends
- For small lift or pump stations
- Powered by RemoteIQ™ Water
- Alarm notifications
- Track pump run-times and cycle
- Reports critical events
- Reduce site visits
- Lower operating costs
- One-year limited warranty
Specifications
Specifications
Brand
Enclosure
- NEMA 4X or DIN-rail mount
Operating Temperature
- -40 °C to +70 °C (-40 °F to +158 °F)
- Modem Op Temp: -40 °C to +85 °C (-40 °F to +185 °F)
Humidity
- 0-90% non-condensing @ +40° C (+104° F)
Serial Port
- RS484/RS232
Cellular Modem
- LTE/CATM1: dual modem utilizing AT&T or Verizon
- Worldwide: FCC, PTCRB and AT&T certified
Analog Inputs
- 1 analog input (0-1V, 0-5V, 0-10V, 4- 20mA)
Digital Inputs
- 3 digital/pulse inputs, dry contacts or closure to ground, 0-10 Hz
Relay Outputs
- 1 Form C relay, NO/NC, 12A @ 120/230 VAC or 28 VDC
Pulse Input Parameters
- Between 10-90% (inclusive) duty cycle at a maximum frequency of 1000 Hz (1msec period)
- Max=32 VDC, greater than or equal to 2.5 VDC is a pulse high, less than or equal to 1.1 VDC is a pulse low
Power Supply
- 100-240VAC to 13.8 VDC, 50-60 Hz, 1.9A, DIN-rail mounted, ULrated
Modes
- Sleep mode: less than 6 mA @ 12 VDC
- Monitoring mode: 70 mA @ 12 VDC
- LTE transmit mode: 400 mA peak @ 12 VDC
Field Wiring
- All I/O wiring is to terminal blocks (10-24 AWG)
Applications
Applications
- Wireless monitoring solution for small water and wastewater applications
- Applications include tanks, flow meters and smaller lift or pump stations
- Reduces operating costs by reporting critical events, automating reports and minimizing site visits
- Monitors data and uses RemoteIQ to manage alarm notifications, system status and reports
- Peer-to-peer options for tank-to-well monitoring and control (utilize with Aquavx system)