Images are representations only.

EliteIQ Wireless SCADA System

Brand: Cattron
The EliteIQ™ is a robust, wireless SACDA water system for remote monitoring, control and alarm notification. It is designed for large pump and lift stations, gas compressor stations, substations, and water and wastewater treatment plants. 

The remote monitoring system is user-configurable with any combination of 48 digital and analog inputs, 24 relay outputs, and 72 Modbus PLC channels to match your requirements.
  • Monitor up to 48 dry contacts or digital inputs, analog inputs or up to 72 Modbus PLC channels.
  • Combine discrete I/O with Modbus PLC channels (optional)
  • Alarm notifications via email, text message or voice calls
  • Alarm conditions:
    • Change of state
    • Limits
    • Rates of change
    • Run-time or cycle limits
  • Automated control functions based on set points and conditions
  • Local user interface via keypad and display
  • Scheduled or on-demand reports via email
Features
  • Modbus RTU Slave allows bi-directional access from SCADA and HMI software giving you complete access to all inputs and outputs through an RS-232/485 serial port
  • Modbus RTU Master allows for reading/writing directly to a PLC or Modbus slave device over a serial Modbus link
  • Optional 8-channel digital and analog input cards, 4-channel relay output cards with a maximum of 48 inputs or 24 outputs
  • NEMA 4X enclosure with clear door and panel/flush mount metal enclosure
  • Camera for incident-based events via on-demand snapshots that become historical data
The EliteIQ™ is a robust, wireless SACDA water system for remote monitoring, control and alarm notification. It is designed for large pump and lift stations, gas compressor stations, substations, and water and wastewater treatment plants. 

The remote monitoring system is user-configurable with any combination of 48 digital and analog inputs, 24 relay outputs, and 72 Modbus PLC channels to match your requirements.
  • Monitor up to 48 dry contacts or digital inputs, analog inputs or up to 72 Modbus PLC channels.
  • Combine discrete I/O with Modbus PLC channels (optional)
  • Alarm notifications via email, text message or voice calls
  • Alarm conditions:
    • Change of state
    • Limits
    • Rates of change
    • Run-time or cycle limits
  • Automated control functions based on set points and conditions
  • Local user interface via keypad and display
  • Scheduled or on-demand reports via email
Features
  • Modbus RTU Slave allows bi-directional access from SCADA and HMI software giving you complete access to all inputs and outputs through an RS-232/485 serial port
  • Modbus RTU Master allows for reading/writing directly to a PLC or Modbus slave device over a serial Modbus link
  • Optional 8-channel digital and analog input cards, 4-channel relay output cards with a maximum of 48 inputs or 24 outputs
  • NEMA 4X enclosure with clear door and panel/flush mount metal enclosure
  • Camera for incident-based events via on-demand snapshots that become historical data

Specifications

Brand

Enclosure

  • NEMA 4X, flush mount or sub-panel mount

Operating Temperature

  • -40 °C to +70 °C (-40 °F to +158 °F)
  • Modem Op Temp: -40 °C to +85 °C (-40 °F to +185 °F)

Humidity

  • 0-90% non-condensing @ +40° C (+104° F)

Serial Port

  • Two serial ports: RS485/RS232

Cellular Modem

  • LTE/CATM1 dual modem utilizing AT&T or Verizon

Battery Backup

  • 12V, 24-hour rechargeable sealed lead acid, 12-hour minimum

Power Supply

  • 90-264 VAC to 24 VDC, 47-63Hz, 1.67A, open frame mount, UL rated

Modes

  • Run Mode: Average current draw is 115 mA with backup battery fully charged. Max current draw is 1A during CELL transmit.
  • Add 15 mA per analog/digital I/O card, add 300 mA per relay card (all relays energized)

Field Wiring

  • All I/O wiring uses quick-disconnect pluggable connectors (12-24 AWG)

Analog Inputs

  • 8-48, 8 per input card, 4-20mA, 0- 1V, 1-5V, 1-10V

Digital Inputs

  • 8-48, 8 per input card, dry contact or digital, 5-24V, NO/NC

Relay Outputs

  • 4-24, 4 per output card, 8A @ 125VAC, 5A @ 30 VDC

Modbus I/O

  • Maximum of 72 Modbus RTU PLC channels in increments of 8